SLA蒸汽電磁閥
SLA系列電磁閥,G1/4---G11/2
適用介質:空氣,瓦斯,水,熱水,油品,蒸汽等
閥體材質:黃銅或不銹鋼
zui大工作壓力:0--4.0MPA
環境溫度:0--80度
介質溫度:普通80度,110度,150度,180度,可以按要求選擇
電源電壓:AC 220V 230V 240V 110V 24V DC 24V 12V
電壓波動幅度:+10%到-10%允許波動
常規備貨:AC220V/230V/240V 50/60HZ DC24V
密封材料:密封件采用聚四氟乙烯材料(Teflon),以適用不同流體的開關控制
·
參數表格:
管 口徑 | 流量 通徑 mm | CV值 | | | | | | | | | zui大 流體 溫度 | 線圈 配置 | | | 線圈 等級 | 外行尺寸 長×寬×高 A×B×H | |
| 空氣 瓦斯 | 水、熱水液體 | 輕油 | 蒸汽 AC/DC | VA AC220V | W DC24V |
zui小 壓力 | AC | DC | AC | DC | AC | DC |
1/8” | 2.5 | 0.23 | 0 | 8 | 8 | 8 | 8 | 6 | 6 | 10 | 180 | D | 22 | 13 | H | 48×25×85.5 | 0.45 |
2.5 | 0.23 | 0 | 13 | 13 | 13 | 13 | 7 | 7 | | 110 | D | 22 | 13 | F | 48×25×85.5 | 0.45 |
2.5 | 0.23 | 0 | 13 | 13 | 13 | 13 | 5 | 5 | | 135 | D | 22 | 13 | H | 48×25×85.5 | 0.45 |
2.5 | 0.23 | 0 | 13 | 13 | 13 | 13 | 7 | 7 | | 80 | D | 22 | 13 | F | 48×25×85.5 | 0.45 |
4.5 | 0.6 | 0 | 7 | 4 | 7 | 4 | 4 | 4 | 7 | 165 | D | 22 | 13 | H | 48×25×85.5 | 0.55 |
4.5 | 0.6 | 0 | 7 | 4 | 7 | 4 | 4 | 4 | | 110 | D | 22 | 13 | F | 48×25×85.5 | 0.55 |
4.5 | 0.6 | 0 | 7 | 4 | 7 | 4 | 4 | 4 | | 135 | D | 22 | 13 | H | 48×25×85.5 | 0.55 |
4.5 | 0.6 | 0 | 7 | 4 | 7 | 4 | 4 | 4 | 7 | 80 | D | 22 | 13 | F | 48×25×85.5 | 0.55 |
1/4” | 2.5 | 0.23 | 0 | 7 | 4 | 7 | 4 | 4 | 4 | 10 | 180 | D | 22 | 13 | H | 58×25×85.5 | 0.4 |
2.5 | 0.23 | 0 | 13 | 13 | 13 | 13 | 7 | 7 | | 110 | D | 22 | 13 | F | 58×25×85.5 | 0.4 |
2.5 | 0.23 | 0 | 13 | 13 | 13 | 13 | 7 | 7 | | 135 | D | 22 | 13 | H | 58×25×85.5 | 0.4 |
2.5 | 0.23 | 0 | 13 | 13 | 13 | 13 | 7 | 7 | | 80 | D | 22 | 13 | F | 58×25×85.5 | 0.4 |
4.5 | 0.6 | 0 | 7 | 4 | 7 | 4 | 4 | 4 | 7 | 165 | D | 22 | 13 | H | 58×25×85.5 | 0.5 |
4.5 | 0.6 | 0 | 7 | 4 | 7 | 4 | 4 | 4 | | 110 | D | 22 | 13 | F | 58×25×85.5 | 0.5 |
4.5 | 0.6 | 0 | 7 | 4 | 7 | 4 | 4 | 4 | | 135 | D | 22 | 13 | H | 58×25×85.5 | 0.5 |
4.5 | 0.6 | 0 | 7 | 4 | 7 | 4 | 4 | 4 | | 80 | D | 22 | 13 | F | 58×25×85.5 | 0.5 |
3/8”
| 15 | 4.5 | 0.5 | 25 | 20 | 25 | 20 | 20 | 20 | | 110 | D | 33 | 32 | F | 75×52×129 | 1.25 |
15 | 4.5 | 0.5 | 25 | 20 | 25 | 20 | 20 | 20 | 10 | 185 | W | 30 | 25 | H | 75×52×129 | 1.25 |
1/2” | 15 | 4.5 | 0.5 | 25 | 20 | 25 | 20 | 20 | 20 | | 110 | D | 33 | 32 | F | 75×52×129 | 1.2 |
15 | 4.5 | 0.5 | 25 | 20 | 25 | 20 | 20 | 20 | 10 | 185 | W | 30 | 25 | H | 75×52×129 | 1.2 |
3/4” | 20 | 9.0 | 0.5 | 25 | 20 | 25 | 20 | 20 | 20 | | 110 | D | 33 | 32 | F | 85×60×141 | 1.5 |
3/4” | 20 | 0.9 | 0.5 | 25 | 20 | 25 | 20 | 20 | 20 | | 110 | D | 33 | 32 | F | 85×60×141 | 1.5 |
20 | 0.9 | 0.5 | 25 | 20 | 25 | 20 | 20 | 20 | 10 | 185 | W | 30 | 25 | H | 85×60×141 | 1.5 |
1” | 25 | 13 | 0.5 | 25 | 20 | 25 | 20 | 20 | 20 | | 110 | D | 33 | 32 | F | 100×70×148 | 1.9 |
25 | 13 | 0.5 | 25 | 20 | 25 | 20 | 20 | 20 | 10 | 185 | W | 30 | 25 | H | 100×70×148 | 1.9 |
11/4” | 35 | 26 | 0.5 | 25 | 20 | 25 | 20 | 20 | 20 | | 110 | D | 33 | 32 | F | 120×90×168 | 3.6 |
35 | 26 | 0.5 | 25 | 20 | 25 | 20 | 20 | 20 | 10 | 185 | W | 30 | 25 | H | 120×90×168 | 3.6 |
11/2” | 35 | 26 | 0.5 | 25 | 20 | 25 | 20 | 20 | 20 | | 110 | D | 33 | 32 | F | 120×90×168 | 3.6 |
35 | 26 | 0.5 | 25 | 20 | 25 | 20 | 20 | 20 | 10 | 185 | W | 30 | 25 | H | 120×90×168 | |
· 備注:線圈配置“H”級用于高溫蒸汽和常溫,介質溫度在185度一下。“F"級只能用于水野氣等常溫介質。
可能發生的故障及其排除方法 :
故 障 | 原 因 | 排除方法 |
接通電源 電磁閥打不開 | 電源電壓太低 線圈燒毀 介質壓力過低 | 調整電壓至使用范圍內 更換線圈 增大管道介質壓力 |
關閉電源 閥關不住或關閉不佳 | 介質壓力過高 膜片損壞或有異物卡住 膜片上方塔簧偏斜 | 減小管道介質壓力 更換新膜片清除異物 重新定位安裝 |
電磁閥安裝注意:
1、安裝時應注意閥體上箭頭應與介質流向*。不可裝在有直接滴水或濺水的地方。電磁閥應垂直向上安裝;
2、電磁閥應保證在電源電壓為額定電壓的15%-10%波動范圍內正常工作;
3、電磁閥安裝后,管道中不得有反向壓差。并需通電數次,使之適溫后方可正式投入使用;
4、電磁閥安裝前應*清洗管道。通入的介質應無雜質。閥前裝過濾器;
5、當電磁閥發生故障或清洗時,為保證系統繼續運行,應安裝旁路裝置。